VACUUM FEED GAS CHLORINATOR

Principle of Operation

Motive Water ( water at high pressure) passes through the injector to produce vacuum. This vacuum extends upto Automatic Vacuum Regulator (AVR). The chlorine gas supplied [from Tonners / Cylinders or Chlorine Evaporators] under pressure is reduced to a lower pressure by Pressure Reducing Valve [PRV] and to a constant vacuum at the AVR. The gas under vacuum passes through a Gas Flowmeter or Rotameter and Flow Control Valve [FCV].

A Differential Pressure Regulator [DPR] is provided for Chlorinators above 6 Kgs/ hr capacity, to control the pressure drop across the Flow meter and also to ensure accurate and steady flow of gas. The chlorine gas then gets mixed with the water at the injector and is then discharged to the point of application. Safety Valves like Check Valve, Emergency Drain Valve, Pressure Relief Valve and Vacuum Relief Valve are provided in this System to make it safe for both Operating Personnel and Equipment’s longevity.


Automatic Vacuum Regulator

  • Normally closed and opens only when vacuum generates, thus regulating the flow of chlorine gas in a controlled approach.
  • Exclusive design ensures least risk factor of handling chlorine gas under high pressure.

Flow Meter

  • Indicates directly the flow of Chlorine gas in ter ms of Grams/ Kilograms/ Pounds consumed per hour.
  • Made of Borosilicate glass and calibrated for10;1 ratio from 100 Gms/hr to 250 Kg/hr.
  • Accuracy is ± 4% of indicated flow.
  • Flow can be adjusted by a specially designed Flow Control Valve engaged with the Flow meter

Safety Valves

  • The system comes with Pressure Relief Valve, Vacuum Relief Valve, Check Valve and Emergency Drain Relief Valve.
  • Ensures safety at all critical moments to both Men and Machinery.
Floor Mounted System
Pedestal Mounted
Note: The above images are for reference purpose, however. As per Client/ Customer Requirements Items may vary / Changes. Accordingly arrangements also vary. (Put it in small /blur text)